FFCH Series – Commercial Downflow Ceiling Heater
IDEAL SPACES | Bathrooms; Offices; Conference Rooms; Lobbies; Waiting Rooms; Enterance Ways
COLORS | White
TEMP RANGE | 45- 90F
CFM |300
RECESSED | 23-3/4″W x 23-3/4″L x 7″D
SURFACE | 16-1/2″W x 20″L x 5-3/4″D
For commercial spaces that need unobtrusive comfort, install this downflow ceiling heater. Deliver powerful warmth to your office, conference room, lobby, waiting room or entranceway.
- Order a surface or recessed enclosure, depending on your ceiling type and available install space. Surface mounting extends only 6 inches into the room, while the recessed enclosure requires only 7 inches of internal clearance
- Optional relays allow you to connect this ceiling heater to your central building management system, so you can control temperatures from one location
- Included thumb pins hold the unit together, freeing both hands for installation on the ceiling surface or within an enclosure
- Choose a narrow pattern to focus heat on one particular area, or a wide pattern to blanket more area. Asymmetrical heating patterns focus output while still providing generous coverage
- The heaters fan waits until the desired temperature is achieved before blowing air into the room, and discharges all residual heat before shutting off
Additional Information
| CATALOG NUMBER | UPC | AMPS4 | VOLTS | PHASE | SHIP WT. (LBS.) |
|---|---|---|---|---|---|
| 6-85360 | |||||
| FFCH548 | 02652 7 | 19.2/14.2/9.6 | 208 | 1-3 | |
| FFCH542 | 02650 3 | 16.7/12.5/8.3 | 240 | 1-3 | 27 |
| FFCH547 | 02651 0 | 14.4/10.8/7.2 | 277 | 1 | |
| FFCH558 | 02655 8 | 24/18.3/12 | 208 | 1-3 | |
| FFCH552 | 02653 4 | 20.8/15.8/10.4 | 240 | 1-3 | 27 |
| FFCH557 | 02654 1 | 18.1/13.7/9 | 277 | 1 |
| 1Factory wired for highest wattage, field convertible to lower wattages. 2Factory wired 1, field convertible to 3. 3On dual-phase units, maximum amp draw is listed. |
| 3For factory installation of above controls, add $60.00 list. Not applicable on 20 or more heaters. 4Amperage shown is for single phase. |
| CATALOG NUMBER | UPC | DESCRIPTION | SHIP WT. (LBS.) |
|---|---|---|---|
| 6-85360 | |||
| FFCHSE | 02643 5 | Surface Mounting Enclosure Only – To Be Used With Above Heater Sections. | 10 |
| FFCHRE | 02640 4 | Recess Mounting Enclosure Only – To Be Used With Above Heater Sections. | 18 |
| FFCHSENW | 14962 2 | Surface mounted Northern White – To Be Used With Above Heater Section. Dim. 20″L x 16 1/2″W x 5 3/4″D. | 10 |
| FFCHRENW | 14964 6 | Recessed mounted Northern White – To Be Used With Above Heater Sections. Dim. 23 3/4″L x 23 3/4W x 7″D. | 18 |
| FFCHT | 02645 9 | Thermostat SPST Range 45 to 95F | 1 |
| FFCH24R | 02649 7 | Relay (Time Delay 45-60 sec. to close when energized) requires 24 volt supply from remote source. | 1 |
| FFCHR12 | 02642 8 | Relay (Time Delay 45-60 sec. to close when energized) requires 120 volt supply from remote source. | 1 |
| FFCHDS | 02638 1 | Power Disconnect Switch (3-Pole) 30 amps, 600 volts, 3, 60 Hz. | 1 |
| FFCHTK | 02646 6 | Trim Ring for mounting on permanent ceiling (cannot be factory installed). | 1 |
| FFCHTR4 | 02647 3 | 208/240V Primary Transformer/24V sec. and 24V holding coil control relay. | 1 |
| FFCHTR7 | 02648 0 | 277V. Primary Transformer/24V sec. and 24V holding coil control relay. | 1 |
Product Manuals and Literature
- FFCH SERIES – COMMERCIAL DOWNFLOW CEILING HEATER Instruction Manual
- FFCH SERIES – COMMERCIAL DOWNFLOW CEILING HEATER Sales Flyer
- FFCH SERIES – COMMERCIAL DOWNFLOW CEILING HEATER Submittal Sheet
- FFCH SERIES – COMMERCIAL DOWNFLOW CEILING HEATER Series 500 Ceiling Mounted Fan Forced Heater Electrical Accessories