CDF SERIES - COMMERCIAL DOWNFLOW CEILING HEATER

CDF SERIES - COMMERCIAL DOWNFLOW CEILING HEATER

IDEAL SPACES | Bathrooms; Offices; Conference Rooms; Lobbies; Waiting Rooms; Entrance Ways

COLORS | Northern White; Navajo White                                                                                            

TEMP RANGE | 45°- 90°F

CFM | 300

RECESSED | 23-3/4” W x 23-3/4” L x 7” D   

SURFACE | 16-1/2” W x 20” L x 5-3/4” D

  • CDFSE “surface enclosures” are designed to mount flat on the ceiling and extend only 6 in. into the room
  • CDFRE “recessed enclosures” have no protrusions outside recess box, allowing the heater to recess only 7 in. into ceiling space. Mounts in T-Bar or permanent ceiling with trim ring
  • 208V and 240V heaters can be field-converted from single- to three-phase operation. 5,000-watt heater can be field-converted to 3,800 or 2,500 watts and 4,000-watt heater to 3,000 or 2,000 watts
  • BMS-compatible with use of relays
  • Three adjustable airflow patterns from 14 ft. ceilings:  wide, narrow or asymmetrical patterns
  • Automatic fan delay eliminates cold drafts on start-up and discharges residual heat from the heater body during shut down
  • Automatic thermal cutout: shuts off the heater in the event of over-heating and reactivates heater when temperature returns to normal
  • Easy installation: Thumb pins align and temporarily

hold enclosure cover to heating section freeing both hands to finish installation

See more HeatersSee more QMark products

Additional Information

CATALOG NUMBER UPC KW(1) VOLTS AMPS PHASE(2) SHIP WT. (lbs.)
CDF548 6 85360 01510 1 4/3/2002 208 19.2/14.2/9.6 1 and 3 27 lbs.
CDF542 6 85360 01508 8 4/3/2002 240 16.7/12.5/8.3 1 and 3 27 lbs.
CDF547 6 85360 01509 5 4/3/2002 277 14.4/10.8/7.2 1 27 lbs.
CDF558 6 85360 01513 2 5/3.8/2.5 208 24.0/18.3/12.0 1 and 3 27 lbs.
CDF552 6 85360 01511 8 5/3.8/2.5 240 20.8/15.8/10.4 1 and 3 27 lbs.
CDF557 6 85360 01512 5 5/3.8/2.5 277 18.1/13.7/9.0 1 27 lbs.
CATALOG NUMBER DESCRIPTION SHIP WT. (LBS.)
CDFSE Surface Mounting Enclosure Only - To Be Used With Above Heater Sections. 10
CDFRE Recess Mounting Enclosure Only - To Be Used With Above Heater Sections. 18
CDFSENW Surface mounted Northern White - To Be Used With Above Heater Section. Dim. 20"L x 16 1/2"W x 5 3/4"D. 10
CDFRENW Recessed mounted Northern White - To Be Used With Above Heater Sections. Dim. 23 3/4"L x 23 3/4W x 7"D. 18
CDFT Thermostat SPST Range 45 to 95°F 1
CDF24R Relay (Time Delay 45-60 sec. to close when energized) requires 24 volt supply from remote source. 1
CDFR12 Relay (Time Delay 45-60 sec. to close when energized) requires 120 volt supply from remote source. 1
CDFDS Power Disconnect Switch (3-Pole) 30 amps, 600 volts, 3Ø, 60 Hz. 1
CDFTK Trim Ring for mounting on permanent ceiling (cannot be factory installed). 1
CDFTR4 208/240V Primary Transformer/24V sec. and 24V holding coil control relay. 1
CDFTR7 277V. Primary Transformer/24V sec. and 24V holding coil control relay. 1
(1) Factory wired for highest wattage, field convertible to lower wattages.
(2) Factory wired 10, field convertible to 30.